-40%

Dental X-ray Machine LK-C27 / BLX-5 / BLX-8Plus + 300 Barrier Envelopes SIZE #2

$ 287.69

Availability: 19 in stock
  • Brand: Unbranded
  • Intended Use/Discipline: Dental Laboratory
  • Modified Item: No
  • Restocking Fee: No
  • Refund will be given as: Money Back
  • Item must be returned within: 60 Days
  • MPN: 1691002110+1170100202+1460300200+1170100100
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Buyer
  • Country/Region of Manufacture: China
  • Custom Bundle: No
  • Condition: New
  • Non-Domestic Product: No
  • Model: LK-C27/BLX-5/ BLX-8Plus

    Description

    Product introduction
    BLX-8Plus
    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz

    and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

    located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz

    and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

    located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use

    After each photo, you have to wait 30 seconds before you can take a normal photo

    TECHNICAL SPECIFICATIONS

    Tube Voltage
    60kV
    Tube Current
    1mA
    Time Exposure
    1~~9s
    High pressure generator
    30kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.3mm(TOSHIBA)
    Charger Input Voltage
    AC110V

    220V
    Supply Frequency
    50Hz±1%
    Radiation Leakage
    <20ugy/h
    Battery
    24V DC 8000MA
    Weight
    4.3KG
    Dimensions
    37 cm×31 cm×28cm (L×W×H)
    Reference of the Angles

    '
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure

    Tooth
    Adult
    Child
    Central & Lateral
    0.8-1.2
    0.8-1.0
    Cuspid & 1st Bicuspid
    1.2-1.4
    1.0- 1.2
    Upper 5

    6
    1.6-1.8
    1.4-1.6
    Upper 7

    8
    3.0-3.5
    2.8-3.3.
    Lower 5

    6
    1.8-2.0.
    1.6-1.8
    Lower 7

    8
    2.0-2.5
    1.8-2.3
    Packing List:
    Main machine   1pcs
    Power line      1pcs
    User manual     1pcs
    Operation of the Main Unit :
    Upon receiving

    open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box.
    Install the blue ray tube to the foreside of the ball head

    then tighten it.
    Turn on the Power

    the pilot lamp will be light up.During this time

    the digital tube  will show the fore setting time. Now the equipment is in standby mode.
    Setting the time (Skip to next step if unneeded) Use the "SET"

    "+"

    and" -" buttons to reset the time as follows: press SET

    the pilot lamp above is illuminated

    the machine is now in the time setting mode

    then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
    Put the Tooth film plumb behind the tooth which is going to be taken picture

    and be as close as possible (the smooth side stick to the tooth)
    Keep the ball head plumb to the tooth projection position; Have the ball head

    tooth

    and tooth film steadily mutually plumb.
    After positioning

    use the ON/OFF on the main Unit

    to take pictures. (Notice: gently press 0.5 sec to turn it on)
    After exposure to the tube

    press the start button again  in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray

    so the dental films can be used again).
    Repeat step 6 to reset the picturing time.To repeat the picturing process

    please repeat steps 7 to 9.
    Turn the power  off when the work is finished

    press POWER

    making sure the pilot lamp is off.Don't keep the machine long in standby mode.
    Operation of the Main Unit :
    Upon receiving

    open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box.
    Install the blue ray tube to the foreside of the ball head

    then tighten it.
    Turn on the Power

    the pilot lamp will be light up.During this time

    the digital tube  will show the fore setting time. Now the equipment is in standby mode.
    Setting the time (Skip to next step if unneeded) Use the "SET"

    "+"

    and" -" buttons to reset the time as follows: press SET

    the pilot lamp above is illuminated, the machine is now in the time setting mode

    then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
    Put the Tooth film plumb behind the tooth which is going to be taken picture

    and be as close as possible (the smooth side stick to the tooth)
    Keep the ball head plumb to the tooth projection position; Have the ball head

    tooth

    and tooth film steadily mutually plumb.
    After positioning

    use the ON/OFF on the main Unit

    to take pictures. (Notice: gently press 0.5 sec to turn it on)
    After exposure to the tube

    press the start button again  in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray

    so the dental films can be used again).
    Repeat step 6 to reset the picturing time.To repeat the picturing process

    please repeat steps 7 to 9.
    Turn the power  off when the work is finished

    press POWER

    making sure the pilot lamp is off.Don't keep the machine long in standby mode.
    +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
    BLX-5
    Specifications
    Voltage: 110v±10% and 220V±10%
    Power: 24V 8000MA
    Charger: 220V/110V, 50Hz
    Tube current: 0.1mA
    Rating: 60W
    Frequency: 30 KHz
    Exposure time: 1-9 seconds optional
    Leak radiation: < 20μgy/h(12lb)
    Focus Skin Distance: >20cm
    Tube voltage: 60KV
    Relative Humidity(RH) < 80%
    Storage conditions: 5-40 degrees Celsius, relative Humidity
    Net weight: 5.5 kg
    Dimension: 47 x 42 x 19 cm
    Operation of the Main Unit
    1. Upon receiving, open the box and check the product for possible damage during shipping.
    2. Make sure the fittings on the encasement list are packaged within the box.
    +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
    LK-C27
    Fetures:
    1.This portable dental X-ray unit is high frequency machine.
    2.The body is small, light weight and nearly no radiation.
    3.It has excellent image quality, portable storage, save more space.
    4.It uses high frequency and DC international power supply.
    5.All of the components installed in the central PC board concentrated. Shock,set-up, electron tubes, all of them are insulation
    vacuum, sealed stereotype protection.
    6.There are also manual buttons installed on the surface of shell, as well as batteries and charges7.This unit mainly suitable for
    oral pre-treatment for learning internal organizational structure, root depth and so on, is indispensable in daily life clinic
    equipment, especially for dental implant surgery.
    8. It also can connect with sensor, is great convenience.
    9. The battery is durable, it can take about 5 hundred images after fully charged.
    10. It can be connected with intra-oral digital X-ray imaging system.
    Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use

    After each photo taking, you need to wait for the normal value to return before taking a normal photo

    Technical Parameter:
    Tube voltage: 60KV
    Tube current: 1mA
    Exposure time: 0.1--2.0s
    Frequency: 30KHz
    Rate power: 60VA
    Distance from skin to cone: 130mm
    Tube focus: 0.3mm*0.3mm
    Battery: DC14.8V 6400mAh
    Charger input voltage: AC100V-240V±10%
    Output voltage: DC16.8V
    Ambient temperature: 5℃~40℃
    Relative temperature: <75%RH
    Net weight: 2.5KG
    Gross weight: 3.5KG
    Size(mm): 138*165*185
    Package size(mm): 220*240*275
    +++++++++++++++++++++++++++++++++++++++++
    300pcs X-Ray Barrier Envelopes
    Introduction
    For use Imaging Plate (Digital Sensor), it is used to protect the IP and avoid cross inflection
    among the doctors and patients .
    300Barrier Envelopes SIZE #2 for Intra Oral X-Ray ScanX Phosphor Storage Plates
    Feature:
    1.Reduce Cross-Infection.
    2.Keep the Phosphor Storage Plate Clean.
    3.Easy to use.
    4.Low cost, Disposable Use.
    5.Compatible with Scan-X Air Techniques and many other brands!
    FDA Statement
    The sale of this item may be subject to regulation by the U.S.
    Food and Drug Administration and state and local regulatory agencies.
    If so, you can bid on this item only if you are an authorized purchaser.
    If the item is subject to FDA regulation,
    I will verify your status as an authorized purchaser of this item before shipping of the item.
    Seller name:2Byoung2016
    City,State:SHENZHEN,China
    Telephone number:0755-15236254
    Shipping
    The goods you odered will be posted out in the second working day after the paymet has been made. (We will inform you via email if any delay occured due to holiday events).
    General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal).
    Payment
    We accept PayPal only.
    The address in your paypal details will be used as the actual shipping adress, please make sure the adress is correct.
    If you are planning on combining your items, please make sure that you wait until ALL auctions have ended before you visit the checkout. All items must be paid within 7 days.
    Feedback
    You feedback is VERY important to us :)
    Please leave us positive feedback, an positive feedback will be automatically left for you once we receive your full payment. Please leave us with any concerns prior to leave negative feedback, as we can only correct issues when we are aware of them. We understand the concerns and frustrations you might have, and will try our best to resolve the isuues.
    Returns
    Exchanges are offered for items that are defective or damaged when received, although this is highly unlikely. After exchanges are made and have not resolved the issue, we will refund the cost of the merchandise.
    Defective items or problems with your order must be reported within 3 days after receiving. Please keep all packaging, documentation, packing list, etc. that came with your order. These will be used to verify claims if there is any problem with you.
    Restocking fee will be charged for returned items without original package or any quality problem.Please contact us for details before returning your package to avoid misunderstanding.
    IMPORTANT: Customer's item must be returned to our facility with the ROF (Return Order Form) at the buyers shipping expense.
    Contact Us
    Serivce is our #1 priority at Dentaltree!
    If you contact us immediately after placing the order, we will make every effort to assist you with your change request. Unfortunately, we can not make changes or cancel an order once it has shipped.
    We offer the best items at the best prices. We strive to exceed all your expectations and put a smile on your face. Your experience will be a pleasant and effortless one when you buy at Dentaltree. We stand behind our products and pride ourselves on OUTSTANDING customer service. We guarantee that you will be delighted with your purchase or we will gladly and promptly issue you a refund or make things right!
    FAQ
    Didn't receive the goods in time?
    Our working time is Monday to Friday GMT AM8:30-PM5:30, we will reply your mail as soon as possible during working hours.
    Didn't receive goods over three month?
    Under normal circumstances, the transport time of the United States is 7-14 days, and about 25 days for Europe,30-35 days for Australia , 50-60 days for South America time.
    We hope you can understand the international transit,there are many uncertain factors beyond our control, such as bad weather,detained by the Customs and so on,we will try to help you solve all your problems.
    Product damage and warranty policy?
    Normal mechanical products are warrantee such as dental handpiece,ultrasonic scaler,curing light and some other product warranty period is 3-6 months.
    On Jan-07-21 at 18:48:09 PST, seller added the following information:
    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local  regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is  subject to FDA regulation, I will verify your  status as an authorized purchaser of this item before shipping of  the item.
    Seller name:dentaltree
    City,State:SHENZHEN,China
    Telephone number:0755-42857928
    Device Classification Name

    System, X-Ray, Mobile
    510(K) Number

    K200976
    Device Name

    SR-8230, SR-8230S Portable X-Ray Unit
    Regulation Number

    892.172
    Classification Product Code

    IZL
    Date Received

    4/13/2020
    Decision Date

    6/10/2020
    Decision

    Substantially Equivalent (SESE)
    Regulation Medical

    Specialty        Radiology
    510k Review Panel

    Radiology
    Summary

    Summary
    Type

    Traditional
    Reviewed By Third Party

    No
    Combination Product

    No