-40%

Dental X Ray Mobile Film Imaging Unit Focus Digital System Machine Low Dose

$ 7.65

Availability: 55 in stock
  • Item must be returned within: 60 Days
  • Modified Item: No
  • MPN: GJ1170100101/1170100210/1170100500
  • Condition: New
  • Brand: Unbranded
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • Intended Use/Discipline: Dental Laboratory
  • Country/Region of Manufacture: China
  • Custom Bundle: No
  • All returns accepted: Returns Accepted
  • Model: BLX-5, BLX-5(8Plus), LK-C27
  • Refund will be given as: Money Back

    Description

    无标题文档
    BLX-5
    Feature:
    1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
    2.) Toshiba 0.3mm x 0.3mm micro-focus tube
    3.) No protective operation room is needed when installing the complete machine.
    4.) Flexible adjustment of position and angle of handpiece
    5.) Compact in volume, light in weight, convenient for carrying
    6.) Time is adjustable, high contrast of picture, imaging in focus
    7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine
    8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
    9.) Non-film inspection and storage can be realized when corresponding to a sensor.
    Specifications:
    Voltage: 110v±10% and 220V±10%
    Power: 24V 8000MA
    Charger: 220V/110V, 50Hz
    Tube current: 0.1mA
    Rating: 60W
    Frequency: 30 KHz
    Exposure time: 1-9 seconds optional
    Leak radiation: < 20μgy/h(12lb)
    Focus Skin Distance: >20cm
    Tube voltage: 60KV
    Relative Humidity(RH) < 80%
    Storage conditions: 5-40 degrees Celsius, relative Humidity
    Net weight: 5.5 kg
    Dimension: 47 x 42 x 19 cm
    Operation of the Main Unit:
    1. Upon receiving, open the box and check the product for possible damage during shipping.
    2. Make sure the fittings on the encasement list are packaged within the box
    LK-C27
    Feature:
    1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
    2.) Toshiba 0.3mm x 0.3mm micro-focus tube
    3.) No protective operation room is needed when installing the complete machine
    4.) Flexible adjustment of position and angle of handpiece
    5.) Compact in volume, light in weight, convenient for carrying
    6.) Time is adjustable, high contrast of picture, imaging in focus
    7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine
    8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
    9.) Non-film inspection and storage can be realized when corresponding to a sensor
    Specifications:
    Voltage: 110v±10% and 220V±10%
    Power: 24V 8000MA
    Charger: 220V/110V, 50Hz
    Tube current: 0.1mA
    Rating: 60W
    Frequency: 30 KHz
    Exposure time: 1-9 seconds optional
    Leak radiation: < 20μgy/h(12lb)
    Focus Skin Distance: >20cm
    Tube voltage: 60KV
    Relative Humidity(RH) < 80%
    Storage conditions: 5-40 degrees Celsius, relative Humidity
    Net weight: 5.5 kg
    Dimension: 47 x 42 x 19 cm
    Operation of the Main Unit:
    1. Upon receiving, open the box and check the product for possible damage during shipping.
    2. Make sure the fittings on the encasement list are packaged within the box
    BLX-5 (8Plus)
    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz

    and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

    located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    TECHNICAL SPECIFICATIONS

    Tube Voltage
    60kV
    Tube Current
    1mA
    Time Exposure
    1~~9s
    High pressure generator
    30kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.3mm(TOSHIBA)
    Charger Input Voltage
    AC110V

    220V
    Supply Frequency
    50Hz±1%
    Radiation Leakage
    <20ugy/h
    Battery
    24V DC 8000MA
    Weight
    4.3KG
    Dimensions
    37 cm×31 cm×28cm (L×W×H)
    Reference of the Angles

    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure

    Tooth
    Adult
    Child
    Central & Lateral
    0.8-1.2
    0.8-1.0
    Cuspid & 1st Bicuspid
    1.2-1.4
    1.0- 1.2
    Upper 5

    6
    1.6-1.8
    1.4-1.6
    Upper 7

    8
    3.0-3.5
    2.8-3.3.
    Lower 5

    6
    1.8-2.0.
    1.6-1.8
    Lower 7

    8
    2.0-2.5
    1.8-2.3
    Packing List:
    Main machine 1pc
    Power line 1pc
    User manual 1pc
    Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use

    After each photo taking, you need to wait for the normal value to return before taking a normal photo

    X-ray Sensor holder
    Description:
    Applied for traditional or smaller dental films and wireless imaging plates (digital sensor).
    During taking picture, it’s better to put the film in the exactly position for making the ill tooth image displayed in the middle of the film.
    Reduces Patient's Oral Discomfort and Allows for Better Accuracy and Ease of X-ray Taking Procedure.
    Specifications:
    Material: plastics
    Excellent Sensor Protection
    Dental X-ray sensor positioner
    For digital sensor with line
    the clamp size can be adjusted for different imaging plates
    Satisfaction Guaranteed
    !
    Package:
    1, (Green) For right maxillary upper premolar/molar and left mandibular
    2, (Blue) For left maxillary premolar and right mandibular premolar/molar
    3, (Yellow) For maxillary/ mandbular incisor -Anterior teeth
    4.( 2pcs small green accessories)Special for smaller sensor, like the introduction book show.
    One suit includes 3 Pcs

    Left, Right, Upper

    Note:
    The item can be sterilize under 131

    ,but not too much time,pls try to do it by disinfectant.
    Barrier Envelopes SIZE #2
    Feature:
    1.Reduce Cross-Infection.
    2.Keep the Phosphor Storage Plate Clean.
    3.Easy to use.
    4.Low cost, Disposable Use.
    5.Compatible with Scan-X Air Techniques and many other brands!
    6.Quantity: 300pcs
    Note:
    For
    use Imaging Plate (Digital Sensor), it is used to protect the IP and avoid cross inflection among the doctors and patients .
    Operation of the Main Unit :
    Upon receiving

    open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box.
    Install the blue ray tube to the foreside of the ball head

    then tighten it.
    Turn on the Power

    the pilot lamp will be light up.During this time

    the digital tube will show the fore setting time. Now the equipment is in standby mode.
    Setting the time (Skip to next step if unneeded) Use the "SET"

    "+"

    and" -" buttons to reset the time as follows: press SET

    the pilot lamp above is illuminated

    the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
    Put the Tooth film plumb behind the tooth which is going to be taken picture

    and be as close as possible (the smooth side stick to the tooth)
    Keep the ball head plumb to the tooth projection position; Have the ball head

    tooth

    and tooth film steadily mutually plumb.
    After positioning

    use the ON/OFF on the main Unit

    to take pictures. (Notice: gently press 0.5 sec to turn it on)
    After exposure to the tube

    press the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray

    so the dental films can be used again).
    Repeat step 6 to reset the picturing time.To repeat the picturing process

    please repeat steps 7 to 9.
    Turn the power off when the work is finished

    press POWER

    making sure the pilot lamp is off.Don't keep the machine long in standby mode.
    STATEMENT :
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. So you can bid it on this item only if you are an authorized purchaser. If the item is subject to FDA regulation,We have to verify your status as an authorized purchaser of this item before shipping of the item. Thanks for your understanding.
    Feedback
    We commited ourselfs to your 100% satisfaction both with our goods and services.
    ? Please leave me FIVE star POSITIVE feedback if you are satisfied with our items.
    ? Please CONTACT me immediately before leave us neutral feedback or negtive feedback, We will try our best to resolve any problem for you untill you are satisfied.
    Shipping
    1. We will send out your orders in one day as soon as we receive your payment.
    2. Delivery ways: TNT, DHL, YANWEN, EMS, USPS, China POST,etc.
    3. Delivery time:10-15 days to USA,
    20-30 days to UK, Germany, French, Australia, Canada, etc, Over 30 days to other countries.
    Payment
    We accept PayPal and bank wire transfer. All payments must be made within 7 days after the auction ends. Non-paying bidders will be reported to eBay. Please don't buy an item if you can't/won't pay for it.
    Paypal is the easiest way to pay for items on eBay. Please make sure your Paypal and eBay accounts have the same physical address used for delivery and the same e-mail address to ensure payment confirmation.
    Shipping: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.
    Returns
    If the item you received is damaged or defective,Please contact us immidately.We will free exchange or refund.
    We will pay the return shipping costs if the product is defective or the return is a result of our error. If the item is returned for any other reason you are responsible for the return shipping charges.
    You can return your purchase for up to 15 days from the date of delivery. No refund will be issued if the product shows signs of use. Returned package must be in the original packaging, everything must be in new condition, No missing parts.
    Our guarantee does not cover accidental damage or wear of product caused by customer.Thank you very much for your understanding!
    Contact Us
    We're one of the largest online dental suppliers based on many qualified manufacturers in china.
    If you contact us immediately after placing the order, we will make every effort to assist you with your change request. Unfortunately, we can not make changes or cancel an order once it has shipped.
    Any help,need or questions, please do not hesitate to contact us. Looking forward  to our friendly & win-win cooperation!
    On Aug-19-20 at 23:49:10 PDT, seller added the following information:
    Device Classification Name
    System, X-Ray, Mobile
    510(K) Number
    K200976
    Regulation Number
    892.172
    Classification Product Code
    IZL
    Date Received
    4/13/2020
    Decision Date
    6/10/2020
    Decision
    Substantially Equivalent (SESE)
    Regulation Medical Specialty
    Radiology
    510k Review Panel
    Radiology
    Summary
    Summary
    Type
    Traditional
    Reviewed By Third Party
    No
    Combination Product
    No