-40%

Dental Portable Handheld Digital X-Ray Machine Unit Surgical Mobile X-Ray BLX-5

$ 279.83

Availability: 100 in stock
  • Model: BLX-5
  • MPN: GJ1170100101
  • Brand: Unbranded
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 30 Days
  • Condition: New
  • Country/Region of Manufacture: China
  • Voltage: 220V/110V, 50Hz
  • Refund will be given as: Money Back
  • All returns accepted: Returns Accepted
  • Restocking Fee: No
  • Intended Use/Discipline: Dental Laboratory

    Description

    Features:
    1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
    2.) Toshiba 0.3mm x 0.3mm micro-focus tube
    3.) No protective operation room is needed when installing the complete machine
    4.) Flexible adjustment of position and angle of handpiece
    5.) Compact in volume, light in weight, convenient for carrying
    6.) Time is adjustable, high contrast of picture, imaging in focus
    7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine
    8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
    9.) Non-film inspection and storage can be realized when corresponding to a sensor
    Specifications
    Voltage: 110v±10% and 220V±10%
    Power: 24V 8000MA
    Charger: 220V/110V, 50Hz
    Tube current: 0.1mA
    Rating: 60W
    Frequency: 30 KHz
    Exposure time: 1-9 seconds optional
    Leak radiation: < 20μgy/h(12lb)
    Focus Skin Distance: >20cm
    Tube voltage: 60KV
    Relative Humidity(RH) < 80%
    Storage conditions: 5-40 degrees Celsius, relative Humidity
    Net weight: 5.5 kg
    Dimension: 47 x 42 x 19 cm
    Content:
    Main Unit x 1
    Dental Film Position x1
    English Manual x 1
    Warranty Card x 1
    Operation of the Main Unit
    1. Upon receiving, open the box and check the product for possible damage during shipping.
    2. Make sure the fittings on the encasement list are packaged within the box.
    3. Connect the six-core cable (of the Main Unit) to the joint of the ball head and tighten the screw
    4. After the Main Unit and ball head are perfectly fit together, plug in the international standard electrical source, grounding is strongly recommended.
    5. Turn on the Power; the pilot lamp will be light up.During this time, the digital tube of the main unit will show the fore setting time. Now the equipment is in standby mode.
    6. Setting the time (Skip to next step if unneeded) Use the "SET", "+", and" -" buttons to reset the time as follows: press SET, the pilot lamp above is illuminated, the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 0.5-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
    7. Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
    8. Keep the ball head plumb to the tooth projection position; Have the ball head, tooth, and tooth film steadily mutually plumb.
    9. After positioning, use theEXP on the main Unit, the remote controller, or the button on the touch head tube to take pictures. The three methods have the same effect. (Notice: gently press)
    10. After exposure to the tube, release the start button again (available in three ways) in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray, so the dental films can be used again).
    Repeat step 6 to reset the picturing time.To repeat the picturing process, please repeat steps 7 to 9.
    11. Turn the power of the main unit off when the work is finished, press POWER, making sure the pilot lamp is off. Don't keep the main unit long in standby mode.
    Points for Attention
    1. Make sure the angle of film, tooth, and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
    2. Remember to turn the power offwhen work is done.
    3. Change the battery if the remote controller loses its functioning or if the remote's distance is shorted.
    4. After turning the power on, wait one minute before taking pictures, this allows the ray to provide a steady output.
    5. The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs,  it will not be able to carry out the normal work of filming.
    6. When taking pictures, the EXP button could stop the objection and then the machine goes back to the preparation mode.
    7. Use high quality tooth film and developing liquid to make clear pictures.
    8. Handle the ball head gently while in use, so as not to damage the delicate component.
    9. Do not pull hard on the cable which connects the ball head to the main unit.
    10. The cable connecting the ball head to the main unit cannot bear the weight of the ball head, so do not raise the ball head by holding the cable, it will cause damage.
    11. We usually set the time between 3-8 seconds when taking pictures, but the actual time of ray output is 0.2-0.5 seconds.
    12. If a situation occurs,  preventing the machine from taking regular pictures,  contact the seller to solve the problem instead of trying to service the product yourself.
    13. Keep the tooth film and the liquid in a proper place and use them within the shelf-life period. While, because the liquid is not allowed to ship by carrier normal, so we take it out before ship, look forward to your understanding.
    14. Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    15. Other requests accordance with the scope of the technical parameters.
    16. Please read the manual carefully before using.
    Payment
    We accept PayPal Only! All payments must be made within 7 days after the auction ends. Non-paying bidders will be reported to eBay. Please don't buy an item
    if you can't/won't pay for it.
    Paypal is the easiest way to pay for items on eBay. Please make sure your Paypal and eBay accounts have the same physical address used for delivery and the same e-mail address to ensure payment confirmation.
    Shipping: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.
    Shipping
    The goods you odered will be posted out in the second working day after the paymet has been made. (We will inform you via email if any delay occured due to holiday events.
    General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal.
    Return
    If the item you received is damaged or defective,Please contact us immidately.We will free exchange or refund.
    We will pay the return shipping costs if the product is defective or the return is a result of our error. If the item is returned for any other reason you are responsible for the return shipping charges.
    You can return your purchase for up to 15 days from the date of delivery. No refund will be issued if the product shows signs of use. Returned package must be in the original packaging, everything must be in new condition, No missing parts.
    Our guarantee does not cover accidental damage or wear of product caused by customer.Thank you very much for your understanding!
    Feedback
    Your feedback is VERY important to us ^_^
    Please leave us positive feedback, an positive feedback will be automatically left for you once we receive your full payment. Please leave us with any concerns prior to leave negative feedback, as we can only correct issues when we are aware of them. We understand the concerns and frustrations you might have, and will try our best to resolve the isuues.
    Contact Us
    Serivce is our #1 priority !
    If you contact us immediately after placing the order, we will make every effort to assist you with your change request. Unfortunately, we can not make changes
    or cancel an order once it has shipped.
    We offer the best items at the best prices. We strive to exceed all your expectations and put a smile on your face. Your experience will be a pleasant and effortless one when you buy . We stand behind our products and pride ourselves on OUTSTANDING customer service. We guarantee that you will be delighted with your purchase or we will gladly and promptly issue you a refund or make things right!
    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory
    agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your
    status as an authorized purchaser of this item before shipping of the item.
    Seller name:
    charmingbaistra
    City,State:SHENZHEN,China
    Telephone number:0755-61297775
    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory
    agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your
    status as an authorized purchaser of this item before shipping of the item.
    Seller name:
    charmingbaistra
    City,State:SHENZHEN,China
    Telephone number:0755-61297775
    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug
    Administration and state and local regulatory agencies. If so, you can bid
    on this item only if you are an authorized purchaser. If the item is subject
    to FDA regulation, I will verify your status as an authorized purchaser of
    this item before shipping of the item.
    Seller name: charmingbaistra
    City,State:SHENZHEN,China
    Telephone number:0755-61297775
    Device Classification Name

    System, X-Ray, Mobile
    510(K) Number

    K200976
    Device Name

    SR-8230, SR-8230S Portable X-Ray Unit
    Regulation Number

    892.172
    Classification Product Code

    IZL
    Date Received

    4/13/2020
    Decision Date

    6/10/2020
    Decision

    Substantially Equivalent (SESE)
    Regulation Medical

    Specialty
    Radiology
    510k Review Panel

    Radiology
    Summary

    Summary
    Type

    Traditional
    Reviewed By Third Party

    No
    Combination Product

    No